摘要
柴油机在研发试验阶段都会通过活塞漏气量来评价活塞、活塞环和缸体的设计质量。通过研究AVL442活塞漏气仪测量机理,发现在台架漏气量的实际测量中,漏出气体的温度、压力与漏气仪测量的参考温度、压力有明显差别,会在一定程度上影响漏气量测量。为此提出一种漏气量测量自动修正方法,在漏出气体进入漏气仪前测量其温度和压力,并基于台架数据采集系统的Calculation、LAM模块配置漏气量修正计算,在漏气量采集过程中自动修正测量值,从而提高台架漏气量测量准确度,提升台架与测试设备的关联分析能力。
Abstract
During the development and testing stage of diesel engine, the matching performance of piston, piston ring and cylinder was usually evaluated by the blow-by. By studying the measurement mechanism of AVL442 blow-by meter, it was found that there was significant difference between the actual temperature and pressure and the reference ones achieved by blow-by meter measurement, which would affect the accurate measurement of blow-by to a certain extent. Automatic correction method of blow-by measurement was hence put forward. The temperature and pressure of blow-by gas were measured before passing through the meter, then blow-by correction algorithm was configured based on the LAM acquisition and formula editing of bench data acquisition system, and the automatic correction was hence conducted during the measurement of blow-by. Accordingly, the correlation between the bench and test equipment was improved, and the accuracy of blow-by measurement was also improved.
关键词
漏气量 /
活塞漏气仪 /
温度测量 /
压力测量 /
修正
Key words
blow-by /
blow-by meter /
temperature measurement /
pressure measurement /
correction
刘杰,陈创,谢俊,董红霞,王宇,李闯.
柴油机台架漏气量测量自动修正方法[J]. 车用发动机. 2024, 0(3): 88-92 https://doi.org/10.3969/j.issn.1001-2222.2024.03.014
LIU Jie,CHEN Chuang,XIE Jun,DONG Hongxia,WANG Yu,LI Chuang.
Automatic Correction Method of Blow By Measurement on Diesel Engine Bench[J]. Vehicle Engine. 2024, 0(3): 88-92 https://doi.org/10.3969/j.issn.1001-2222.2024.03.014
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}